  1. W

    Salary Raise for Getting PE License

    $750 cash award and reimbursement of fees to take the test.
  2. W

    Nevada-PE Results

    I received a letter in the mail box with a take home test on Nevada laws and a stamp order form.
  3. W

    STAMP

    I just ordered the standard rubber stamp directly from the Board. It was 25$ from the Nevada Board and $150 for the license and certificate.
  4. W

    Nevada-PE Results

    I passed. Las Vegas- Electrical
  5. W

    STAMP

    Hey Guys I am wondering if anyone has ordered their stamp yet? I am torn between the standard and Self inking type. Its 15$ more for the self inking one.. Is it worth it? Any suggestions?
  6. W

    OFFICIAL EB.com MEMBER'S RESULTS THREAD

    I passed Electrical- Nevada
  7. W

    New Test Format

    This was my second attempt. I found the new syllabus a lot easier to study and to take the test. I guess it depends on what you are more comfortable with. To me, I found the old syllabus too vast and I sucked at it. I scored a 67 last time and I thought I did a lot worse than that so I am...
  8. W

    How was your testing Venue?

    Reynolds Boy Scout Center in Las Vegas, Nevada. No complaints at all about the venue. Very nice and very comfortable. Quiet and peaceful.
  9. W

    Power Portion

    I wanted to thank everyone on here for answering my questions and all the good suggestions. I think I did fairly well, hopefully it is well enough to pass. I am trying to get a feel for how others performed and what they thought of the test (Easy/Medium/Hard). Thanks everyone...
  10. W

    Good reference

    Guys, Here is what I have on Insulation Resistance testing. Its a nice outline. http://www.aemc.com/techinfo/techworkbooks...tech_megohm.pdf
  11. W

    NEW NCEES problem # 512

    Can someone please throw some light on why the answer shows Z 500ft as (0.035+j 0.049) /4?? I understand the Z1000ft value and to me, the answer for Z 500ft should be Z1000ft /2 and since there are 2 sets of conductors, shouldnt we multiply Z by 2 to get the value for Z 500ft for 2 sets of...
  12. W

    Power Factor Correction Caps

    Thanks for the response. I don't understand why the voltage won't increase. Isn't one of the advantages of power factor correction caps to reduce voltage drop? Meaning voltage is increased?
  13. W

    Power Factor Correction Caps

    Can someone please share some information on power factor correction capacitors and some of the effects of using them on motors. Will the current at the motor terminals decrease? Will the voltage increase?? Thank You
  14. W

    NCEES power # 113

    Thank you. That makes sense now :)
  15. W

    NCEES power # 113

    Can someone please explain this to me. How did they come up with 1/180, 1/90 seconds and so on? Thanks
  16. W

    Cogeneration Sample question

    HI!!! This is going to be my second attempt at this test. I remember there were some problems on co- generation the first time that I took the test but I can't seem to find any sample questions in the books that I have. Atleast none with calculations involved. Can anyone refer some books or...