Search results

Professional Engineer & PE Exam Forum

Help Support Professional Engineer & PE Exam Forum:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.
  1. S

    Free PDH Courses!

    Hi. I am from Japan. And I couldn't register Japanese phone number in the registration form. Could you tell me how do I proceed further?
  2. S

    Q 513, 530, 540

    @Ahmed S. You can choose transformer 7.5 MVA as Sbase and do the calculation. You will get the same result.
  3. S

    October 2019 P.E. ELECTRICAL POWER

    Board: JPEC Test taken from Tokyo, JPN.
  4. S

    October 2019 P.E. ELECTRICAL POWER

    Finally passed. YEAH!! -Jpn
  5. S

    Free giveaway! - New Practice Exam for the PE by Electrical PE Review just released

    Hi Zach, i tried too many times but still the same problem☹️
  6. S

    Free giveaway! - New Practice Exam for the PE by Electrical PE Review just released

    Tried many times. Still invalid ☹️
  7. S

    Shorebook Q27

    This question is for finding the condition where system stability is maintained after the fault. From equal angle criteria, for stability of system: area C = area B. Since network restores at 80deg and the power equations are not given we assume this as critical clearing angle. "Critical...
  8. S

    Graffeo: Ind. Motor

    can you try with wildi method as well plz.
  9. S

    Graffeo: Ind. Motor

    From Wildi equation 15.8: For max power/torque; R2/S=IZ1I where R2= 0.3 Z1= r1+jx = 0.2+j(0.25+0.35) = 0.2+j0.6 = 0.632<71.6 deg Therfore, S=R2/IZ1I = 0.3/0.632 = 0.475
  10. S

    GLOVER SOLUTION MANUAL

    You can find hand written pdf solution 3rd edition somewhere in the internet.
  11. S

    NEC - Capacitors with motors

    @LyceeFruit @tpkjr2006 Thank you for your kind suggestion. I do have the 2017 version as well.
  12. S

    How Old are you?

    I am 32 Passed FE 1st try Jan 2018 ( from JPN) Failed PE 1st try Oct 2018 PE 2nd try target on Oct 2019
  13. S

    Graffeo: Ind. Motor

    Still waiting for someone to response on this.
  14. S

    Open Wye - Open Delta

    Thank you Zach for the attachment, and happy to say that is what i followed. I believe Open wye must be the same approach like open delta that you have mentioned. I wonder if some one agree with my above answers so that i can know i am in right track .
  15. S

    NEC - Capacitors with motors

    My understanding  may be incorrect but i see the 460.9 statement as following: "When a capacitor is connected on the load side of the motor overload device, line current will be reduced due to an improved power factor, which must be taken into account when selecting the rating of a motor...
  16. S

    NEC Code questions

    If no other adjustments or correction factors are given use 75degC. You can see in NEC'17_Annex D Example D7 doing the same .
  17. S

    Graffeo: Ind. Motor

    I tried to solve Graffeo Ex38 by Wilid method but i got different answers than one in the Graffeo. I think i am missing something with my calculation. Please let me know who have done this problem with Wildi method. For those who don't know the question: "A 120V, 6OHz, 6 pole, delta...
  18. S

    Graffeo: Ind. Motor

    Sorry for the late response. Thank you  @ellen3720 for your kind suggestion. I do have Wildi book. I just want to know if Graffeo Pmax came from same logic as mentioned in Wildi. Yes definitely i will follow Wildi. :)