I have some confusion on the ratio
On Q118, the delta - wye ratio did not take the sqrt 3 into the consideration on the ratio.
13.2/132
But on the Q506, delta-wye ratio, sqrt 3 is taken into consideration
why?
Basically a few other similar across spin up tests.
Why voltage at the load their answer required the load 480V divided by 1.73 then multiply by 1.73?
I thought you only need divide by 1.73
My solution:
Z = 0.5+j0.08 (750/1000) = 0.38 <9.1
Vt= 480/1.73 - (100<-36.9)(0.38<9.1)
=...
Can I use the MVA method instead the pu method?
3 phase generator serves a 5/25kV transformer rated 6MVA. The generator's subtransient impedance is j0.39pu and the transformer rated impedance is 6%. If the generator is rated 11MVA, its contribution (MVA) under fault condition at the...
I did ok on most of the subject even better than average but this 3 subjects killed me
5 - Circuit Analysis: Devices & Power Electronic Circuits
7 Rotating Machines & Electromagnetic Devices:Electromagnetic Devices - 1 correct out of 6
10 Transmissions & Distribution: Protection...