Recent content by H2OEngineer

Professional Engineer & PE Exam Forum

Help Support Professional Engineer & PE Exam Forum:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.
  1. H

    Hiner Problem #19

    Hi Ptatohed, will pm you now.
  2. H

    Everything you wanted to know about the CA-Survey/Seismic Civil PE Exams

    I took the Seismic yesterday and feel I did very well. I had studied Hiners book, and two weeks before the exam I purchased EET´s practice exams. I am very glad I purchased the EET practice exam and feel they made all the difference. One of the problems on the Seismic exam was identical to the...
  3. H

    Civil Surveying Exam - Passing Score

    What is considered a passing score for the Civil Surveying exam?
  4. H

    Hiner Problem #19

    Thank you for all your help on the Seismic Exam material ptatohed. I feel I did very well on the exam this morning! I am now on to studying surveying. I have Mahallati´s book for surveying, although I am only into the first chapter (just started this afternoon after the seismic exam) I am...
  5. H

    Hiner Problem #19

    ptatohed Apologies for resurrecting this question again but it is still not sitting right with me. Your comment above stated: So, you used the Southwest (bottom, left) corner as your 0,0, right? Thus, measuring from center down to Wall 2, you get -50'. Measuring from center up to Wall 1, you...
  6. H

    EET Exam-3 Problem #33 F=12.4?

    Thank you, will contact him directly.
  7. H

    EET Exam-3 Problem #33 F=12.4?

    Can someone please explain where the force of F2 = 12.4 kips is derived from as shown in the solution?
  8. H

    Seismic - Nailing Problems & Unit Roof Shear (ASD and LRFD)

    You talked me into getting the EET practice exams, hopefully they will arrive quickly. If I had a few more weeks I would have purchased the workbook as well for a fresh approach after using Hiner. Yes, I am taking the Surveying as well. I have Mahallati´s review book coming, can you recommend...
  9. H

    Seismic - Nailing Problems & Unit Roof Shear (ASD and LRFD)

    Thank you both for the help! Steven
  10. H

    Seismic - Nailing Problems & Unit Roof Shear (ASD and LRFD)

    Can someone please confirm or correct my understanding on the following? When working nailing problems using American Wood Council Tables 4.2A and 4.2B for horizontal diaphragms we use ASD force unit roof shear (0.7xVunit-roof) and compare to half the tabulated values in the AWC tables...
  11. H

    Hiner Multiple Choice Question 6.18

    Thank you, yes it clarifies it for me.
  12. H

    Hiner Multiple Choice Question 6.18

    The question wording is a bit confusing. The questions asks: " Determine the governing wall anchorage force (Fp) at the Level 1 (and Level 2) flexible floor diaphragms." The solution takes the weight to be 1/2 the wall of story 1 plus 1/2 the wall of story 2. Is the problem really just...
  13. H

    Hiner Problem #19

    Excellent, yes that clarifies it for me. I had originally thought it was based on the origin to CR, but talked myself out of it based in part on the moved sign you noted with mac force on Wall A. Thank you again! Steven
  14. H

    Hiner Problem #19

    Yes. The solution for Max F on Wall 2 uses Mt2 with ey as -5.0 ft and yielding -1500 kip'-ft for Mt2. The second negative sign shown in the solution for Max F on Wall 2 is on d using -50ft. When evaluating the moment with ey2 equaling -5.0 ft the rotation provides an additive force to Wall...
Back